Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Surg Res ; 178(2): 571-7, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22748597

RESUMO

BACKGROUND: We used speckle-tracking echocardiography to test the hypothesis that regional left ventricular (LV) strain would improve during optimized biventricular pacing (BiVP) in acute right ventricular (RV) pressure overload (PO). MATERIALS AND METHODS: Complete heart block and RVPO were induced in five open-chest fully anesthetized pigs. BiVP was optimized by adjusting atrioventricular and interventricular delays to maximize cardiac output derived from an aortic flow probe. LV short axis views were obtained during atrio-RV pacing (RVP), atrio-LV pacing (LVP), and BiVP. Intraventricular synchrony was assessed by comparing speckle-tracking echocardiography-derived time to peak (TTP) strain in the anterior septal (AS) and posterior wall segments. Segmental function was assessed using radial strain. RESULTS: Cardiac output was higher with optimized (RV first) BiVP than with LVP (0.96 ± 0.26 L/min versus 0.89 ± 0.27 L/min; P = 0.05). AS TTP strain (502 ± 19 ms) during LVP was prolonged versus BiVP (392 ± 58 ms) and versus RVP (390 ± 53 ms) (P = 0.0018). AS TTP strain during LVP was prolonged versus posterior (502 ± 19 ms versus 396 ± 72 ms, P = 0.0011). No significant difference in TTP strain in these segments was seen with BiVP or RVP. Posterior strain (20% ± 5%) increased 66% versus AS strain (12% ± 6%) during BiVP (P = 0.0029). A similar increase occurred during RVP (posterior 20% ± 3% versus AS 12% ± 7%, P = 0.0002). Posterior strain did not increase during LVP. CONCLUSIONS: BiVP and RVP restore intraventricular LV synchrony and increase regional function versus LVP during RVPO. RV pre-excitation unloads the RV and reduces the duration of AS contraction, facilitating synchrony of all LV segments and increasing free wall LV contraction.


Assuntos
Terapia de Ressincronização Cardíaca , Disfunção Ventricular Direita/terapia , Função Ventricular Esquerda , Animais , Débito Cardíaco , Masculino , Contração Miocárdica , Suínos , Disfunção Ventricular Direita/fisiopatologia
3.
J Thorac Cardiovasc Surg ; 142(1): 73-6, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20965517

RESUMO

OBJECTIVE: Temporary biventricular pacing to treat low output states after cardiac surgery is an active area of investigation. Reoperative cases are not studied due to adhesions, which preclude left ventricular mobilization to place epicardial pacing wires. In such patients, inserting a temporary left ventricular lead via the coronary sinus cardioplegia cannula may allow for biventricular pacing. We developed a novel technique for intraoperative left ventricular lead placement. METHODS: Eight domestic pigs underwent median sternotomy and pericardiotomy. Temporary pacing wires were sewn to the right atrium and right ventricle. Complete heart block was induced by ethanol ablation of the atrioventricular node. A 13-French retrograde cardioplegia catheter was introduced via the right atrial free wall into the coronary sinus. A 6-French left ventricular pacing lead was inserted into the cardioplegia catheter and advanced into the coronary sinus during biventricular pacing until left ventricular capture was detected by electrocardiogram and arterial pressure monitoring. Left ventricular capture success rate and electrical performance were recorded during five placement attempts. RESULTS: Left ventricular capture was achieved on 80% of insertion attempts. Left ventricular capture without diaphragmatic pacing was achieved in 7 pigs. Lead tip locations were mostly in lateral and posterior basal coronary vein branches. There were no arrhythmias, bleeding, or perforation associated with lead insertion. CONCLUSIONS: Intraoperative biventricular pacing with a left ventricular pacing lead inserted via the coronary sinus cardioplegia cannula is feasible, using standard instrumentation and without requiring cardiac manipulation. This approach merits further study in patients undergoing reoperative cardiac surgery.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Procedimentos Cirúrgicos Cardíacos , Catéteres , Seio Coronário , Parada Cardíaca Induzida/instrumentação , Animais , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Catéteres/efeitos adversos , Eletrocardiografia , Estudos de Viabilidade , Parada Cardíaca Induzida/efeitos adversos , Hemodinâmica , Cuidados Intraoperatórios , Pericardiectomia , Reoperação , Esternotomia , Sus scrofa , Fatores de Tempo , Função Ventricular Esquerda
4.
J Thorac Cardiovasc Surg ; 141(4): 1002-8, 1008.e1, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20800242

RESUMO

OBJECTIVE: Permanent biventricular pacing benefits patients with heart failure and interventricular conduction delay, but the importance of pacing with and without optimization in patients at risk of low cardiac output after cardiac surgery is unknown. We hypothesized that pacing parameters independently affect cardiac output. Accordingly, we analyzed aortic flow measured with an electromagnetic flowmeter in patients at risk of low cardiac output during an ongoing randomized clinical trial of biventricular pacing (n = 11) versus standard of care (n = 9). METHODS: A substudy was conducted in all 20 patients in both groups with stable pacing after coronary artery bypass grafting, valve surgery, or both. Ejection fraction averaged 33% ± 15%, and QRS duration was 116 ± 19 ms. Effects were measured within 1 hour of the conclusion of cardiopulmonary bypass. Atrioventricular delay (7 settings) and interventricular delay (9 settings) were optimized in random sequence. RESULTS: Optimization of atrioventricular delay (171 ± 8 ms) at an interventricular delay of 0 ms increased flow by 14% versus the worst setting (111 ± 11 ms, P < .001) and 7% versus nominal atrioventricular delay (120 ms, P < .001). Interventricular delay optimization increased flow 10% versus the worst setting (P < .001) and 5% versus nominal interventricular delay (0 ms, P < .001). Optimized pacing increased cardiac output 13% versus atrial pacing at matched heart rate (5.5 ± 0.5 vs 4.9 ± 0.6 L/min, P = .003) and 10% versus sinus rhythm (5.0 ± 0.6 L/min, P = .019). CONCLUSIONS: Temporary biventricular pacing increases intraoperative cardiac output in patients with left ventricular dysfunction undergoing cardiac surgery. Atrioventricular and interventricular delay optimization maximizes this benefit.


Assuntos
Baixo Débito Cardíaco/prevenção & controle , Débito Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Disfunção Ventricular Esquerda/cirurgia , Aorta/fisiopatologia , Baixo Débito Cardíaco/etiologia , Baixo Débito Cardíaco/fisiopatologia , Ponte de Artéria Coronária/efeitos adversos , Eletrocardiografia , Frequência Cardíaca , Valvas Cardíacas/cirurgia , Humanos , Cuidados Intraoperatórios , Cidade de Nova Iorque , Fluxo Sanguíneo Regional , Reologia , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...